other

SFP+ 16G C17-C61 DWDM 20KM DDM Optical Transceiver


Product Features


  • Supports up to 14.025Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:
  • Standard:  0 to +70°C


Applications


  • 4.25/8.5/14.025G Fibre channel
  • Other Optical links





  • 产品详细信息


RSPD-16GD20-CXX
14.025Gbps SFP+ DWDM Transceiver, Single Mode, 20km Reach




Description


  • The SFP+ transceivers are high performance, cost effective modules supporting data rate of 14.025Gbps and 20km transmission distance with SMF.
  • The transceiver consists of three sections: a Cooled EML laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
  • The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.


Transceiver functional diagram


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4.5

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

-

5

85

%


Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0


+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc



550

mA

Data Rate


4.25

14.025


Gbps


Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

1528.77


1563.86

nm


Spectral Width(-20dB)

Δλ



1

nm


Side-Mode Suppression Ratio

SMSR

30

-


dB


Average Output Power

Pout

-1


+3

dBm

1

Extinction Ratio

ER

8.2



dB


Data Input Swing Differential

VIN

180


850

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω


TX Disable

Disable


2.0


Vcc

V


Enable


0


0.8

V


TX Fault

Fault


2.0


Vcc

V


Normal


0


0.8

V


Receiver

Centre Wavelength

λc

1260


1620

nm


Receiver Sensitivity




-14

dBm

3

Receiver Overload


0.5



dBm

3

LOS De-Assert

LOSD



-15

dBm


LOS Assert

LOSA

-28



dBm


LOS Hysteresis


0.5



dB


Data Output Swing Differential

Vout

300


900

mV

4

LOS

High

2.0


Vcc

V


Low



0.8

V


Notes:

1. The optical power is launched into SMF.

2. PECL input, internally AC-coupled and terminated.

3. Measured with a PRBS 231-1 test pattern @14025Mbps, BER ≤1×10-12.

4. Internally AC-coupled.


Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on



2

ms

Tx Disable Assert Time

t_off



100

µs

Time To Initialize, including Reset of Tx Fault

t_init



300

ms

Tx Fault Assert Time

t_fault



100

µs

Tx Disable To Reset

t_reset

10



µs

LOS Assert Time

t_loss_on



100

µs

LOS De-assert Time

t_loss_off



100

µs

Serial ID Clock Rate

f_serial_clock


100

400

KHz

MOD_DEF (0:2)-High

VH

2


Vcc

V

MOD_DEF (0:2)-Low

VL



0.8

V


Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

 0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 100

mA

±10%

Internal

TX Power

-1 to +3

dBm

±3dB

Internal

RX Power

-16 to -1

dBm

±3dB

Internal


Ordering information

Part Number

Product Description

RSPD-16GD20-C17

SFP+ C17 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C18

SFP+ C18 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C19

SFP+ C19 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C20

SFP+ C20 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C21

SFP+ C21 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C22

SFP+ C22 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C23

SFP+ C23 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C24

SFP+ C24 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C25

SFP+ C25 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C26

SFP+ C26 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C27

SFP+ C27 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C28

SFP+ C28 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C29

SFP+ C29 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C30

SFP+ C30 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C31

SFP+ C31 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C32

SFP+ C32 DWDM, 14.025Gbps, LC, 20km, 0°C~+70C, with DDM

RSPD-16GD20-C33

SFP+ C33 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C34

SFP+ C34 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C35

SFP+ C35 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C36

SFP+ C36 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C37

SFP+ C37 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C38

SFP+ C38 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C39

SFP+ C39 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C40

SFP+ C40 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C41

SFP+ C41 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C42

SFP+ C42 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C43

SFP+ C43 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C44

SFP+ C44 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C45

SFP+ C45 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C46

SFP+ C46 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C47

SFP+ C47 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C48

SFP+ C48 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C49

SFP+ C49 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C50

SFP+ C50 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C51

SFP+ C51 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C52

SFP+ C52 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C53

SFP+ C53 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C54

SFP+ C54 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C55

SFP+ C55 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C56

SFP+ C56 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C57

SFP+ C57 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C58

SFP+ C58 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C59

SFP+ C59 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C60

SFP+ C60 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C61

SFP+ C61 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
China SFP 1.25G 1270-1610nm CWDM 150KM DDM Optical Transceiver 1.25G 1270-1610nm CWDM 150KM DDM SFP 光模块
1.25G SFP optical transceiver module, support 1.25Gb/s and up to 150 km transmission Features: Up to 1.25Gb/s Data Links Hot-Pluggable Duplex LC connector Up to 150km on 9/125μm SMF 1270~1610nm CWDM DFB laser transmitter APD Receiver Single +3.3V Power Supply Monitoring Interface Compliant with SFF-8472 Maximum Power <1W Commercial operating temperature range: -0°C to 70°C Version available RoHS compliant and Lead Free Applications: Metro/Access Networks 1.25 Gb/s 1000Base-EZX Ethernet 1×Fibre Channel Other Optical Links
DCI 4x100G QSFP28 转400G CFP2 DCO 板卡 FW841
产品特性: 单板支持4*100G转400G相干传输,可实现单路400G线路侧传输。 波长可调,支持最大400G 75GHz * 64波,400G 100GHz*48波。 具备灵活的相干调制技术:DP-16QAM,DP-8QAM,DP-QPSK。 具备多种FEC纠错技术:oFEC,CFEC,SCFEC,SDFEC。 支持灵活业务接入功能:100GE, 100GE KR4, OTU4和100G FlexE。 支持完善的性能监控和统计功能。 支持高精度板卡温度,电压,电流及功耗实时监控。 客户侧支持多种模块接口类型:100GSR4/CWDM4/LR4/PSM4。 支持统一网管平台,网管方式SNMP、CLI、Web、NMS(图形化界面)。
25G SFP28 Transceiver 25G SFP28 Optical Transceiver
25G SFP28 optical transceiver module, support 25Gb/s and SR up to 100 m transmission, LR 25G SFP28 up to 10 km transmission, and ER 25G SFP28 up to 40 km transmission, it works in high-speed IDC connection solutions, and so on.
管理型交换机 4光24电千兆管理型交换机 FW4024G
24*10/100/1000Mbps RJ45端口+4*千兆SFP端口 FW4024G是一款全千兆三层网管型交换机,产品采用新一代高性能硬件和软件平台,提供灵活、高性价比的全千兆接入和上行端口,支持三层路由协议、完备的安全防护机制、完善的ACL/QoS策略和丰富的VLAN功能,易于管理维护,满足用户对于网络设备易管理、高安全、低成本的组网需求,适用于校园、酒店及企业园区网络接入、汇聚、核心多种应用场景。
Dual Fiber 8CH CWDM MUX DEMUX 8路 双纤双向 1470-1610nm CWDM 波分复用 LGX 盒子模块
CWDM MUX DEMUX,Multiplexing up to 8 Channels on Fiber Pair Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks
Single Fiber 4Channels(8waves) 1470-1610nm CWDM MUX/DEMUX , LC/UPC, Plug-in LGX Box and 2slot 1U Rack Single Fiber 4Channels(8waves) 1470-1610nm CWDM MUX/DEMUX , LC/UPC, Plug-in LGX Box and 2slot 1U Rack
Single-fiber Bidirectional Transmission: Enables 4-channel (8-wavelength) bidirectional transmission over one fiber, supporting 8 types of services. Dual-direction Wavelength Separation: Independent A/B side wavelength ranges (1470–1530nm/1550–1610nm) eliminate interference. Passive Design: No power supply required, ensuring low power consumption and easy maintenance. Flexible deployment: Plug-in LGX module + 2-slot 1U rack, space-saving and easy installation. High Reliability: Low insertion loss (≤2.4dB), high return loss (≥45dB), and wide operating temperature range (-40°C to 85°C). Multi-service Adaptability: Supports 1G/10G Ethernet, SDH/SONET, etc., suitable for broadcast, finance, cloud, and other industries. Intelligent Monitoring: MON port enables online link monitoring without disrupting traffic.
工业级电交换 千兆2光8电PoE 交换机
支持通过5类以太网线的无线访问点(AP)和网络监控摄像头供电 1~8端口支持标准IEEE802.3af供电  (做at标准请特殊说明) 8个10/100/1000 Mbps 自适应RJ45端口 2个上联口为1000Mbps  SFP光纤接口 支持端口自动翻转(Auto MDI/MDIX) 流控方式:全双工采用IEEE 802.3x标准,半双工采用Back pressure标准 符合IEEE 802.3 10Base-T和IEEE 802.3u 100/1000Base-TX标准 每端口最大 15.4W 采用存储转发的交换机制 所有端口支持线速交换,64~9000帧长范围内均可达到线速
24 MPO/MTP接口 网络分光器 8组48芯MPO/MTP 1分2多模 OM4 50:50网络流量复制 1U机箱 24 MPO/MTP接口 网络分光器 8组48芯MPO/MTP 1分2多模 OM4 50:50网络流量复制 1U机箱
在当今网络信息爆增的时代,数据流量是以几何方式递增,光通信已逐步替代原电口通信;原利用网络交换机端口来做镜像数据采集,将会占用交换机越来越多的端口,造成资源的浪费,及成本的上升,同时也无法满足网络安全后端分析设备递增的需求。为此FIBERWDM瑞东光电将您提供更加可靠的光纤网络流量100%复制工具网络流量复制设备NETWORK OTAP(网络分光器),本产品为无源产品,支持各种不同光速率,100%复制主链路流量,而不会对主路造成数据丢包影响;为后端分析设备提供原主路100%数据流量;解决占用主交换机镜像端口问题。
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系