SFP+ 16G C17-C61 DWDM 20KM DDM Optical Transceiver


Product Features


  • Supports up to 14.025Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:
  • Standard:  0 to +70°C


Applications


  • 4.25/8.5/14.025G Fibre channel
  • Other Optical links





  • 产品详细信息


RSPD-16GD20-CXX
14.025Gbps SFP+ DWDM Transceiver, Single Mode, 20km Reach




Description


  • The SFP+ transceivers are high performance, cost effective modules supporting data rate of 14.025Gbps and 20km transmission distance with SMF.
  • The transceiver consists of three sections: a Cooled EML laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
  • The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.


Transceiver functional diagram


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4.5

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

-

5

85

%


Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0


+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc



550

mA

Data Rate


4.25

14.025


Gbps


Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

1528.77


1563.86

nm


Spectral Width(-20dB)

Δλ



1

nm


Side-Mode Suppression Ratio

SMSR

30

-


dB


Average Output Power

Pout

-1


+3

dBm

1

Extinction Ratio

ER

8.2



dB


Data Input Swing Differential

VIN

180


850

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω


TX Disable

Disable


2.0


Vcc

V


Enable


0


0.8

V


TX Fault

Fault


2.0


Vcc

V


Normal


0


0.8

V


Receiver

Centre Wavelength

λc

1260


1620

nm


Receiver Sensitivity




-14

dBm

3

Receiver Overload


0.5



dBm

3

LOS De-Assert

LOSD



-15

dBm


LOS Assert

LOSA

-28



dBm


LOS Hysteresis


0.5



dB


Data Output Swing Differential

Vout

300


900

mV

4

LOS

High

2.0


Vcc

V


Low



0.8

V


Notes:

1. The optical power is launched into SMF.

2. PECL input, internally AC-coupled and terminated.

3. Measured with a PRBS 231-1 test pattern @14025Mbps, BER ≤1×10-12.

4. Internally AC-coupled.


Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on



2

ms

Tx Disable Assert Time

t_off



100

µs

Time To Initialize, including Reset of Tx Fault

t_init



300

ms

Tx Fault Assert Time

t_fault



100

µs

Tx Disable To Reset

t_reset

10



µs

LOS Assert Time

t_loss_on



100

µs

LOS De-assert Time

t_loss_off



100

µs

Serial ID Clock Rate

f_serial_clock


100

400

KHz

MOD_DEF (0:2)-High

VH

2


Vcc

V

MOD_DEF (0:2)-Low

VL



0.8

V


Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

 0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 100

mA

±10%

Internal

TX Power

-1 to +3

dBm

±3dB

Internal

RX Power

-16 to -1

dBm

±3dB

Internal


Ordering information

Part Number

Product Description

RSPD-16GD20-C17

SFP+ C17 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C18

SFP+ C18 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C19

SFP+ C19 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C20

SFP+ C20 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C21

SFP+ C21 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C22

SFP+ C22 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C23

SFP+ C23 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C24

SFP+ C24 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C25

SFP+ C25 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C26

SFP+ C26 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C27

SFP+ C27 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C28

SFP+ C28 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C29

SFP+ C29 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C30

SFP+ C30 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C31

SFP+ C31 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C32

SFP+ C32 DWDM, 14.025Gbps, LC, 20km, 0°C~+70C, with DDM

RSPD-16GD20-C33

SFP+ C33 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C34

SFP+ C34 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C35

SFP+ C35 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C36

SFP+ C36 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C37

SFP+ C37 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C38

SFP+ C38 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C39

SFP+ C39 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C40

SFP+ C40 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C41

SFP+ C41 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C42

SFP+ C42 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C43

SFP+ C43 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C44

SFP+ C44 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C45

SFP+ C45 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C46

SFP+ C46 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C47

SFP+ C47 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C48

SFP+ C48 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C49

SFP+ C49 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C50

SFP+ C50 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C51

SFP+ C51 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C52

SFP+ C52 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C53

SFP+ C53 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C54

SFP+ C54 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C55

SFP+ C55 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C56

SFP+ C56 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C57

SFP+ C57 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C58

SFP+ C58 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C59

SFP+ C59 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C60

SFP+ C60 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C61

SFP+ C61 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
光开关切换设备 24路 4选1 MPO接口 光开关切换设备
具有插入损耗小,切换速度快等特点。 光开关内部电路自检测,故障报警告知。 串口RS-232,以太网RJ45通信接口。 采用 LCD 显示屏,非常直观的显示光路状态,方便用户的操作。 可通过按键和串口、网口发送指令控制光路切换设置。并可通过串口指令锁定按键操作。
100G CFP Module 100G CFP2 LR4 single Rate 10km Module
Features Supports single-rate 103.1Gb/s aggregate(100GE); Lane bit rate 25.78 Gb/s 100GbE; Up to 10km transmission on SMF; LAN WDM laser and PIN receiver; High speed I/O electrical interface (CAUI-4); MDIO interface with integrated Digital Diagnostic monitoring; CFP2 MSA package with duplex LC connector; Single +3.3V power supply; Maximum power consumption 6W; Operating case temperature: -5 to +70 °C; Complies with IEEE802.3bm; Complies with EU Directive 2015/863/EU;   Application 100GBASE-LR4;
MEMS Fiber Optical Switch 1XN MEMS 光开关
Features Proven MEMS durability and reliability Compact Form Factor Fast switching time Qualified to Telcordia GR-1073-CORE and RoHS Applications Opticalsignal switching androuting Optical network protection and restoration Optical path monitoring (Workingwith OTDR or OCM) Instrumentation resource sharing
MPO转LC光分支设备 MPO转LC光分支设备
主要优势: 无损速度转换:将 MPO 分拆为 4 个独立的 LC 接口;完全透明,无需配置。 面向未来:支持: 40G SR4、40G PSM4 分拆为 4×10G 100G SR4、100G PSM4 分拆为 4×25G 400G SR4 分拆为 4×100G
400G网络分光器 400G SR8 MPO16/APC 1分2多模 OM4 50:50网络流量复制 1U机箱 400G网络分光器 400G SR8 MPO16/APC 1分2多模 OM4 50:50网络流量复制 1U机箱
无源设计:无需供电,节省能源与维护成本。 高容量分光:支持 8 条 400G SR8 MPO-16 链路,16 个 OTAP 端口,实现双芯双向流量复制。 流量无损复制:分光比 50:50,100% 镜像主链路流量,不影响主路性能。 低损耗高性能:插损≤4.8dB,均匀性≤0.8dB,回波损耗≥55dB,确保信号稳定传输。 宽温适应性:工作温度 - 40℃~+85℃,适合恶劣环境。 紧凑机架式:1U 机箱(440×230×44mm),节省机柜空间。 多模 OM4 支持:适配 850nm 波长,满足高速短距传输需求。 应用场景:用于交换机、防火墙、服务器等设备间的数据采集与分析,解决端口镜像资源占用问题。
光开关切换设备 24路2选1光开关切换设备
插卡2选1光切换,1U, 2U, 4U 机箱设计,密度集成度高 具有插入损耗小,切换速度快等特点 可通过串口指令或以太网口指令方式进行光路切换设置
网管平台(NMU) 网管平台(NMU)
支持热插拔,失效后不影响业务板卡的正常工作。 支持本地、远程在线升级同时不影响业务板卡的正常工作。 支持基于SNMP统一网管平台,网管方式CLI、Web、NetView(图形化界面)。 支持带内、带外级联网管及提供3个SFP光口、2个RJ45电口和1个Console串口。 提供强大的多层次网络拓扑管理功能,实现网络拓扑快速自动发现并生成直观生动的显示图形。 遵循TMN规范,实现了设备管理、监视与部署、软件升级管理、配置文件管理、告警和性能管理等功能,实现从设备级到网络级全方位的网络管理。
12PIN 微型单路光模块 12PIN 微型单路光模块
12PIN微型单路光模块,主要应用于光背板传输、数字雷达阵列、以太网、 Sonet/SDH/FC、交换机等各种数字光纤通信领域,具有体积小、抗振动、抗干扰等特点。模块外形使用全金属结构,采用12Pin排针电 接口,增加I2C 管理接口,优化信号排针设计。内置单路光发射组件和单路光接收组件,工作波长850nm/1310nm/1550nm。工作温度(环境温度)范围为-40℃~85℃。模块支持单通道传输速率1 .25Gbps~10.3125Gbps。
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系