Product Features


  • Supports up to 14.025Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:
  • Standard:  0 to +70°C


Applications


  • 4.25/8.5/14.025G Fibre channel
  • Other Optical links





  • 产品详细信息


RSPD-16GD20-CXX
14.025Gbps SFP+ DWDM Transceiver, Single Mode, 20km Reach




Description


  • The SFP+ transceivers are high performance, cost effective modules supporting data rate of 14.025Gbps and 20km transmission distance with SMF.
  • The transceiver consists of three sections: a Cooled EML laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
  • The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.


Transceiver functional diagram


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4.5

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

-

5

85

%


Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0


+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc



550

mA

Data Rate


4.25

14.025


Gbps


Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

1528.77


1563.86

nm


Spectral Width(-20dB)

Δλ



1

nm


Side-Mode Suppression Ratio

SMSR

30

-


dB


Average Output Power

Pout

-1


+3

dBm

1

Extinction Ratio

ER

8.2



dB


Data Input Swing Differential

VIN

180


850

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω


TX Disable

Disable


2.0


Vcc

V


Enable


0


0.8

V


TX Fault

Fault


2.0


Vcc

V


Normal


0


0.8

V


Receiver

Centre Wavelength

λc

1260


1620

nm


Receiver Sensitivity




-14

dBm

3

Receiver Overload


0.5



dBm

3

LOS De-Assert

LOSD



-15

dBm


LOS Assert

LOSA

-28



dBm


LOS Hysteresis


0.5



dB


Data Output Swing Differential

Vout

300


900

mV

4

LOS

High

2.0


Vcc

V


Low



0.8

V


Notes:

1. The optical power is launched into SMF.

2. PECL input, internally AC-coupled and terminated.

3. Measured with a PRBS 231-1 test pattern @14025Mbps, BER ≤1×10-12.

4. Internally AC-coupled.


Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on



2

ms

Tx Disable Assert Time

t_off



100

µs

Time To Initialize, including Reset of Tx Fault

t_init



300

ms

Tx Fault Assert Time

t_fault



100

µs

Tx Disable To Reset

t_reset

10



µs

LOS Assert Time

t_loss_on



100

µs

LOS De-assert Time

t_loss_off



100

µs

Serial ID Clock Rate

f_serial_clock


100

400

KHz

MOD_DEF (0:2)-High

VH

2


Vcc

V

MOD_DEF (0:2)-Low

VL



0.8

V


Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

 0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 100

mA

±10%

Internal

TX Power

-1 to +3

dBm

±3dB

Internal

RX Power

-16 to -1

dBm

±3dB

Internal


Ordering information

Part Number

Product Description

RSPD-16GD20-C17

SFP+ C17 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C18

SFP+ C18 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C19

SFP+ C19 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C20

SFP+ C20 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C21

SFP+ C21 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C22

SFP+ C22 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C23

SFP+ C23 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C24

SFP+ C24 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C25

SFP+ C25 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C26

SFP+ C26 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C27

SFP+ C27 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C28

SFP+ C28 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C29

SFP+ C29 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C30

SFP+ C30 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C31

SFP+ C31 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C32

SFP+ C32 DWDM, 14.025Gbps, LC, 20km, 0°C~+70C, with DDM

RSPD-16GD20-C33

SFP+ C33 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C34

SFP+ C34 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C35

SFP+ C35 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C36

SFP+ C36 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C37

SFP+ C37 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C38

SFP+ C38 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C39

SFP+ C39 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C40

SFP+ C40 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C41

SFP+ C41 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C42

SFP+ C42 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C43

SFP+ C43 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C44

SFP+ C44 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C45

SFP+ C45 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C46

SFP+ C46 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C47

SFP+ C47 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C48

SFP+ C48 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C49

SFP+ C49 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C50

SFP+ C50 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C51

SFP+ C51 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C52

SFP+ C52 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C53

SFP+ C53 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C54

SFP+ C54 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C55

SFP+ C55 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C56

SFP+ C56 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C57

SFP+ C57 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C58

SFP+ C58 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C59

SFP+ C59 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C60

SFP+ C60 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C61

SFP+ C61 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
Dual Fiber 8CH CWDM MUX DEMUX 8路 双纤双向 1470nm~1610nm CWDM 带 监控口 LGX 盒子模块
CWDM MUX DEMUX, Multiplexing up to 8 Channels on Fiber Pair 1% Monitor Port for Signal Analyzing or Troubleshooting Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks
DCI 4x100G QSFP28 转400G CFP2 DCO 板卡 FW841
产品特性: 单板支持4*100G转400G相干传输,可实现单路400G线路侧传输。 波长可调,支持最大400G 75GHz * 64波,400G 100GHz*48波。 具备灵活的相干调制技术:DP-16QAM,DP-8QAM,DP-QPSK。 具备多种FEC纠错技术:oFEC,CFEC,SCFEC,SDFEC。 支持灵活业务接入功能:100GE, 100GE KR4, OTU4和100G FlexE。 支持完善的性能监控和统计功能。 支持高精度板卡温度,电压,电流及功耗实时监控。 客户侧支持多种模块接口类型:100GSR4/CWDM4/LR4/PSM4。 支持统一网管平台,网管方式SNMP、CLI、Web、NMS(图形化界面)。
China SFP 1.25G TX 1550 RX 1490 CWDM 180KM DDM   光模块 SFP 1.25G TX 1550 RX 1490 CWDM 180KM DDM 光模块
Features: Up to 1.25Gb/s Data Links Hot-Pluggable Single LC connector Up to 180km on 9/125μm SMF 1550nm DFB laser transmitter APD Receiver Single +3.3V Power Supply Monitoring Interface Compliant with SFF-8472 Power dissipation<1.5W operating temperature range: 0°C to 70°C RoHS compliant and Lead Free Applications: 1000Base-ZX Ethernet Metro/Access Networks 1×Fibre Channel Other Optical Links
网管平台(NMU) 网管平台(NMU)
支持热插拔,失效后不影响业务板卡的正常工作。 支持本地、远程在线升级同时不影响业务板卡的正常工作。 支持基于SNMP统一网管平台,网管方式CLI、Web、NetView(图形化界面)。 支持带内、带外级联网管及提供3个SFP光口、2个RJ45电口和1个Console串口。 提供强大的多层次网络拓扑管理功能,实现网络拓扑快速自动发现并生成直观生动的显示图形。 遵循TMN规范,实现了设备管理、监视与部署、软件升级管理、配置文件管理、告警和性能管理等功能,实现从设备级到网络级全方位的网络管理。
5G前传半有源波分复用系统 5G前传半有源波分复用系统 助力运营商5G快速部署
功能特点 支持无线前传及其它业务综合接入,兼顾无线前传、专线、家宽业务承载,最大化前传网络价值; 最大程度节省光纤,一芯光纤可承载9路4G & 5G前传CPRI/eCPRI业务; 局端有源、远端无源,采用WDM技术扩展纯透明传输的物理通道,无时延和抖动引入; 支持对各通道的收发光功率的监测功能,易于维护、故障定位; 支持光层1:1保护,保护倒换时间小于20ms,提升网络可靠性; 光层保护功能板可根据应用场景选配,支持热插拔、掉电/上电保持功能,保证设备在掉电情况下不影响业务运行; 支持SNMP、Web等多种图形化界面网管; 局端有源设备支持交流220V 、直流-48V供电可选,1+1电源输入保护; 安装方式灵活,局端设备支持机架式安装和挂墙安装,远端设备支持机架式、抱杆和壁挂安装,安装简易,即插即用; 远端室外型设备满足IP67标准要求,支持抱杆和壁挂安装。
网络分光器 16口 1分2 分光比80:20单模 1310/1550nm LC 1U机箱 网络分光器
产品特点 低插损,不影响数据流量包。 无需电源,无需IP址址,无需MAC地址,100%无源产品,性能安全可靠 安装和操作简单,非专业人士即可独立完成。 16个OTAP端口,支持8路主链路串接,数据流量复制;可替代8个交换机镜象端口。 成本低,集成度高
Single Fiber 2CH 4waves1470-1530nm CWDM OADM, WEST AND EAST, LC/UPC, FMU Plug-in Module, and 2 Slots 1U Rack Single Fiber 2CH 4waves1470-1530nm CWDM OADM, WEST AND EAST, LC/UPC, FMU Plug-in Module, and 2 Slots 1U Rack
Single-fiber bidirectional transmission: Supports 2-channel Drop/Add services over a single fiber, optimizing scarce fiber resources. Low insertion loss: ≤1.5dB for wave-to-line, ≤2.4dB for west-east/east-west transmission, ensuring efficient signal propagation. High isolation: ≥30dB adjacent channel isolation and ≥45dB non-adjacent isolation, minimizing crosstalk. Wide temperature tolerance: Operates/stores between -40°C to 85°C, suitable for extreme environmental conditions. Modular deployment: FMU plug-in module compatible with 2-slot 1U rack or LGX BOX for flexible installation.
工业级轨式 1路 RS-485 串口服务器 工业级轨式 1路 RS-485 串口服务器
功能特性 采用ARM Cortex -M4,主频192MHz处理器; 支持1路百兆以太网;以太网支持10/100Base-T(X)自适应以太网接口;支持自动协商(Auto-Nego Full&half duplex),支持自动交叉线检测(MDI/MDIX); 提供1路RS485串口,支持300bps-921600bps线速无阻塞通信,支持波特率自动扫描匹配,支持客户自定义波特率; 支持支持Modbus TCP,TCP Server、TCP Client、UDP Server、UDP Client,等多种工作模式; 完成Modbus-RTU到Modbus-TCP透明转换,实现通过网络方式读取串口设备数据; 支持串口状态和串口参数监视,通信状态一目了然; 支持过网关,跨路由通信;支持虚拟串口驱动访问模式和网络中断自动恢复连接功能; 灵活的串口数据分帧设置,满足用户各种分包需求; 支持标准TCP/IP SOCKET应用程序访问,TCP支持多连接,满足4个以内用户同时监控或管理串口设备; UDP方式下支持单机或多机通讯,满足多个用户同时监控或管理串口设备; 支持Windows配置工具、串口和WEB等多种配置形式、支持SNMP网管; 支持本地和远程的系统固件升级; 支持B/S构架的SNMP网管软件,来统一网管多台串口服务器。 RS485接口有三级防雷保护,防雷达到GB/T17626.5(IEC61000-4-5) 短路电流波10/700μs,开路峰值输出电压6KV,内阻40欧标准; 支持宽范围5-70V交流与直流电源输入,电源接口具有6kV防雷能力; 电源支持过载保护、防反接保护;符合工业四级电磁兼容性要求; 超强防雷功能:防雷击,可抗感应高压,防浪涌等; 无风扇高效散热,降低修复时间; 导轨或壁挂式安装; 宽温型:工作温度-40℃~ +85℃;
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系